HT89DF HIM

Water Softener with Iron & Manganese Reduction Featuring 1" Porting

The HIM Series two-tank system tackles multiple water problems with a single solution. Engineered for efficiency, it combines water softening with iron and manganese reduction capabilities. The system effectively reduces iron and manganese, improving water taste, odor, and clarity while preventing staining on laundry, fixtures, and plumbing.

Hydrotech branded neoprene pressure tank jackets are optional.

Key Features

Maximum Hardness: Softens up to 75 grains per gallon of hardness.

Maximum Total Iron: Removes 10.0 ppm total iron in water with a pH below 7.2 and 7.0 ppm total iron in water with a pH above 7.2.

Total Iron Calculation = (Iron ppm x 1) + (Manganese ppm x 2).

Maximum Manganese: 5.0 ppm (see total iron calculation).

Tank Features: Brine tank with safety float, air check and injection molded brine grid to reduce salt bridging. Optional neoprene pressure tank jacket.

Valve Features

Professionally Engineered for Performance

MODEL NUMBER HT89DF-100HIM HT89DF-150HIM HT89DF-200HIM HT89DF-250HIM HT89DF-300HIM
Item Number 15102100 15102118 15102127 15102130 15102133
FACTORY SETTINGS - IRON & MANGANESE
Salt Used Per Regeneration12.0 lbs18.0 lbs24.0 lbs30.0 lbs36.0 lbs
Water Used Per Regeneration124.0 gal ±10%215.0 gal ±10%274.0 gal ±10%276.0 gal ±10%278.0 gal ±10%
Hardness Removal (Grains)30,00045,00060,00075,00090,000
Filter Media Volume - Cubic Feet1.0 ft³1.5 ft³2.0 ft³2.5 ft³3.0 ft³
GarnetYesYesYesYesYes
Pressure Tank Size (Inches)10 x 5412 x 5213 x 5414 x 6514 x 65
Media LoadedYesYesNoNoNo
Salt Storage Capacity270 lbs350 lbs350 lbs350 lbs420 lbs
Flow Rate @ 15 psi Pressure Drop11.0 US gpm11.2 US gpm12.2 US gpm12.4 US gpm12.6 US gpm
Flow Rate @ 25 psi Pressure Drop15.0 US gpm15.1 US gpm16.2 US gpm16.4 US gpm16.6 US gpm
Backwash Flow Rate2.4 US gpm4.0 US gpm5.0 US gpm5.0 US gpm5.0 US gpm
Shipping Weight120 lbs161 lbs214 lbs250 lbs300 lbs
Regeneration TypeDOWNFLOW (COCURRENT)
Maximum Hardness75 GRAINS PER GALLON
Maximum Total Iron (Ferrous)
Total Iron = (Iron ppm x 1) +
(Manganese ppm x 2)
10.0 PPM TOTAL IRON FOR PH < 7.2
7.0 PPM TOTAL IRON FOR PH >= 7.2
Maximum Manganese
(See Total Iron)
5.0 ppm
Resin TypeAQUAFINE® FINE MESH ION EXCHANGE RESIN
Plumbing ConnectionsINCLUDES 1" 90° NPT ELBOWS
Electrical RequirementsINPUT 120V 60 Hz - OUTPUT 12V 650mA
Water Temperature LimitsMIN 40° - MAX 110° F (4° - 43° C)
Water Pressure LimitsMIN 30 - MAX 125 PSI (207 - 862 KPA)

Not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Peak flow rates are intended for intermittent use only (10 minutes or less) and are for residential applications only. Do not use peak flow rate for commercial applications or for a continuous rate when treated water supplies are geothermal heat pump, swimming pool, etc. For satisfactory operation, the pumping rate of the well system must equal or exceed indicated backwash flow rate.

Contact Customer Service or Your sales representative for application guidelines.

Dimensions

89DFHIM 100 150 200 250 300
TANK/VALVE
A x B (inches)
63 x 10 61 x 12 63 x 13 75 x 14 75 x 14
BRINE TANK
C x D (inches)
18 x 34 20 x 37 20 x 37 20 x 37 23 x 40
80155268