HT89BAF

Reduce Iron, Manganese and Sulphur Without Chemicals

The BAF uses a two-tank design to reduce stubborn iron, manganese and sulfur without chemicals. The first tank contains a pocket of compressed air that aids in the precipitation of iron into solid form. The second tank reduces the solidified iron as it passes through the media bed. The birm media acts as a catalyst in the reaction between iron and air that also causes the iron to precipitate into a solid. Birm is not consumed in the iron removal process, making it more economical than many other iron filtration systems.

Key Features

Natural Oxidation: Reduces iron, manganese and hydrogen sulfide (H2S) without chemicals, air pumps or a venturi.

High Flow Rates: For large residential and commercial applications.

Efficient Regeneration: The BAF regenerates less frequently and uses up to 50% less water than single-tank iron filters. Periodic automatic regeneration replenishes the supply of air and removes iron from the media bed.

Valve Features

Professionally Engineered for Performance

Specifications HT89DF-100BAF HT89DF-150BAF HT89DF-200BAF HT89DF-300BAF
15550980-1 15550901-1 15550902-1 15550903-1
Service Flow Rate 3.0 US gpm 4.0 US gpm 5.0 US gpm 6.0 US gpm
Peak Flow Rate 6.0 US gpm 10.0 US gpm 12.0 US gpm 14.0 US gpm
Backwash Flow Rate 5.0 US gpm 5.0 US gpm 7.0 US gpm 10.0 US gpm
Media (Cubic Feet) 1.0 ft³ 1.5 ft³ 2.0ft³ 3.0 ft³
Pressure Tank Size (Inches) 9 x 48 10 x 54 12 x 52 14 x 65
Air Contact Tank Size (Inches) 9 x 48 10 x 54 12 x 52 14 x 65
Shipping Weight 102 lbs 129 lbs 145 lbs 216 lbs
Media Loaded Yes Yes No No
Maximum Iron 30.0 ppm
Hydrogen Sulfide 1.0 ppm
Manganese 0.0 ppm
Iron Bacteria Removal No
pH 7.0 - 8.5
Plumbing Connections INCLUDES 1" 90° NPT ELBOWS
Electrical Requirements INPUT 120V 60 Hz - OUTPUT 12V 650mA
Water Temperature Limits MIN 40° - MAX 110° F (4° - 43° C)
Water Pressure Limits MIN 30 - MAX 125 PSI (207 - 862 KPA)

At stated service flow rates the pressure drop through these devices will not exceed 15 PSIG.

Not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Peak flow rates are intended for intermittent use only (10 minutes or less) and are for residential applications only. Do not use peak flow rate for commercial applications or for a continuous rate when treated water supplies are geothermal heat pump, swimming pool, etc. For satisfactory operation, the pumping rate of the well system must equal or exceed indicated backwash flow rate.

Contact Customer Service or Your sales representative for application guidelines.

Dimensions

89BAF Filter 100 150 200 300
TANK/VALVE
A x B (inches)
60 x 23 66 x 24 64 x 26 78 x 34
80155268